Air and AC Power with One PTO Opening
Totally contained underdeck within the truck’s frame rails, the patented Genair® dual power system replaces the need for
separate engine-drive air compressors, generators, or power inverters by providing everything you need in a single integrated
unit with one PTO opening. The Genair® is the perfect choice for plastic pipe fusion, TV pipeline inspection, and other on-board
air compressor/AC electric power demands.
| Generator |
| Output (Peak) (kW) | 7.2 | 11.6 |
|---|
| Shipping Weight (lbs.) | 72 | 92 |
|---|
| Height (in.) | 10.5 | 12.0 |
|---|
| Width (in.) | 8.0 | 9.0 |
|---|
| Length (in.) | 14.0 | 15.0 |
|---|
| Voltage (volts) | 120 or 120/240 | 120 or 120/240 |
|---|
| Phase | Single Phase | Single Phase |
|---|
| Speed (rpm) | 3600 |
3600 |
|---|
| Air Compressor |
| CFM |
Air PSI |
Compressor Input |
Compressor Oil Capacity |
Mounted Weight (Dry) |
| 125 |
100 to 150 |
1900 rpm |
3.5 gal. |
550 lbs. |
| 160 |
100 to 150 |
2325 rpm |
3.5 gal. |
550 lbs. |
| 175 |
100 to 150 |
2500 rpm |
3.5 gal. |
550 lbs. |
Product improvement is a continuing goal. Design and specifications are subject to change without notice or obligations.
SPECIAL FEATURES
- Provides constant power input without belts, pulleys, or tensioning devices.
- Vanguard Lifetime Warranty on air end
- Compressor capacities from 125 to 175 cfm
- Electric capacities peak of 7.2 kW and 11.6 kW producing 120 or 120/240 volts at a constant 60 Hz
- Precise frequency controls keep output regulated within 2%
- Electric engine speed controller maintains truck’s engine at required rpm
- Ground fault circuits and outlet panels available to your needs
- Driven by either a sidemount or split-shaft PTO
- Can run air compressor and AC generator separately or simultaneously
- US Patent #1223-343-123: air end and generator unit
- Ideal for pipeline sewer inspection, plastic pipe fusion, auxiliary lighting, and on-board air compressor and AC electric power requirements
Safety Equipment
- Built-in overspeed protection
- Ground fault interrupter circuit
- Remote-mounted control panel
- Air pressure-relief safety valve
- Minimum pressure valve
- Oil fill plug safety relief
Instrumentation
- Conveniently located, easy-to-read instrumentation panel featuring an hour meter, pressure gauge, temperature gauge
Options/Accessories
- Welder option
- Dual Voltage – 120/240 AC
- Dual pressure
- Service/control line moisture separators
- Filter/lubricator/regulator (FLR)
- Air hoses, hose reels, and fittings
- OSHA safety valve (velocity fuse)
- Sullair® air tools
- Tool oiler/lubricator
- Frequency meter
- Voltage meter
Bid Specifications